Train Torsional Analysis
- 회전기계(Compressor, Pump 등)의 경우, Driven Equipment와 Driver를 연결시켜주는 Coupling이 함께 설계되며, (별다른 요청사항이 없을 경우) 전체 Train Rotor를 포함하는 Torsional Vibration을 수행해야 함.
- Coupling의 경우, 회전기계를 구성하는 Rotor 중에서 Torsional 비틀림 강성이 낮게 설계되므로, Coupling Hubs, Spacer 등을 반드시 포함시켜 Analysis를 진행해야 함.
[Modeling for Torsional Vibration, 비틀림 진동 모델]
- Train Torsional vibration analysis 수행에 대한 API (American Petroleum Institute) Requirements는 다음과 같이 제시되어 있음.
* Reference Paragraph, API 617, 9th
- Para. 6.8.6.1, For trains including motors, generators, positive displacement units, or gears, the vendor having unit responsibility shall ensure that a torsional vibration analysis of the complete coupled train is carried out and be responsible for directing any modifications necessary to meet the requirements of 6.8.6.3 through 6.8.6.8.
- Para. 6.8.6.2, lf specified, for direct driven turbine trains, the vendor shall perform a torsional vibration analysis of the complete coupled train and be responsible for directing any modifications necessary to meet the requirements of 6.8.6 .3 through 6.8.6.8.
- Train Torsional Analysis를 수행하지 않고 개별 Rotor에 대해서만 Analysis를 수행할 경우 문제점.
- Driven or Driver Equipment의 Rotor 자체에 대한 Torsional Natural Frequency만 평가되고, Coupling 결합에 의한 해석이 제외됨에 따라, 운전 영역에 따라 왜곡된 해석 결과가 나타날 수 있음.
[필요성, Train Torsional Vibration Analysis]
http://kor.inertance.com/torsional-vibration/
http://www.inertance.com/mechanical/torsional-vibration/
소음·진동 관련 문의는 02-707-1545
또는 admin@inertance.com으로 연락바랍니다
주식회사 이너턴스
'진동기준 및 측정방법' 카테고리의 다른 글
Vibration Criteria Curves (BBN Criterion) (0) | 2024.04.05 |
---|---|
Vibration Criteria for Compressor Skid, API 618 (0) | 2023.05.23 |
건축물 실내 진동 기준 (ISO-10137) (0) | 2023.04.26 |
건축물 진동 기준 (대한건축학회) (0) | 2023.04.21 |
Pressure drop by Pulsation control device (0) | 2023.01.30 |