본문 바로가기
플랜트 기계배관 진동 기준

Pulsatsion Study for Reciprocating Pump, Design Selection

by 이너턴스 2024. 1. 12.

Pulsatsion Study for Reciprocating Pump, Design Selection

(왕복동 압축기의 맥동 분석의 Design Analysis 선정 Guide)

 

API 688 2nd (Pulsation and Vibration Control for Positive Displacement Machinery Systems for Petroleum, Chemical, and Natural Gas Industry Services)에서는 API 674 3rd로 설계되는 왕복동 펌프(Reciprocating Pump)Pulsation study 수행 여부를 판단할 수 있는 Selection Guide를 포함하고 있다.

 

[Pulsastion Analysis Selection Chart]   

Speed, *1) Rated Power per Pump
Hp < 100
(kW < 75)
100 hp ≤ 200
(75 ≤ kW ≤ 150)
Hp > 200
(kW > 150)
Speed < 50 % of Max.
Allowable
No acoustic or
mechanical analysis
Piping system
mechanical review
Acoustic simulation
and piping system
mechanical review
50 % ≤ Speed ≤ 75 % Piping system
mechanical review
Acoustic simulation
and piping system
mechanical review
Acoustic simulation
and mechanical analysis
75 % < Speed Acoustic simulation
and piping system
mechanical review
Acoustic simulation and
mechanical analysis
Acoustic simulation and
mechanical analysis

*1) Speed: Maximum Operating Speed as a % of the Maximum Allowable Speed

 

한편, 상기 Table에서 언급하고 있는 Maximum Allowable speed PumpStroke length에 따라 아래와 같이 구분하여 평가할 수 있다.

 

[Maximum Allowable speed Table]  

Stroke Length RPM for a Single-acting
Plunger Pump
RPM for a Double-acting
Piston-type Pump
mm in.
50 2 450 140
75 3 400 127
100 4 350 116
125 5 310 108
150 6 270 100
175 7 240 94
200 8 210 88
250 10 168 83
300 12 140 78
350 14 120 74
400 16 105 70

 

 

[왕복동 압축기 Acoustic Model, Example]

 

주식회사 이너턴스는 소음진동 전문설계 업체로서 Pulsation Study를 포함하여, 아래와 같은 Engineering Service를 제공하고 있습니다.

 

-       Environmental Noise    

-       Noise Survey    

-       Stability Analysis     

-       Torsional Vibration Analysis   

-       Acoustic Induced Vibration   

맥동 관련 문의는 02-707-1545