Acoustic Induced Vibration (AIV) 평가 기준
- Energy Institute Guideline 2nd edition에 따른 평가
- 배관 형상, 공정 조건에 따른 LOF (Likelihood Of Failure) 값 평가 후 아래 기준치 적용
- LOF 검토 결과에 따른 후속 공정 제안
The response caused by high frequency acoustic excitation affects the pipework downstream of the source to the first major vessel, e.g. separator, KO drum. The assessment generates a main line LOF value at each welded discontinuity, e.g. SBC, Welded Tee, Welded support. It is at the discontinuities with an LOF equal to one where corrective actions are required. The sources of high frequency acoustic excitation are pressure reducing devices such as control / relief valves, restriction orifices, or branch connections. |
[ Criteria for Acoustic Induced Vibration ]
* 출처: Guidelines for the avoidance of vibration induced fatigue failure in process pipework, 2nd edition, January 2008, Energy Institute
음향 유발 진동, 배관 진동, 고유진동수, LOF, 난류 - (주)이너턴스
공장 내 각종 밸브의 작동 시, 높은 소음이 배관 내부로 방출되며, 이너턴스(INERTANCE)에서는 이런 고주파 음향 가진 에 대한 배관 Fitting Selection (O-Let) 등의 건전성을 평가 하고 있습니다. 음향 유
kor.inertance.com
음향 유발 진동 (Acoustic Induced Vibration, AIV)
배관 진동(Pipe Vibration), 음향 피로(Acoustic Fatigue), Energy Institute, 고주파 음향 가진 (H...
blog.naver.com
음향유발진동(AIV) 관련 문의는 02-707-1545 또는
admin@inertance.com으로 연락바랍니다.
주식회사 이너턴스
'플랜트 기계배관 진동 기준' 카테고리의 다른 글
Design Criteria for Torsional Virbation, Reciprocating Pump (0) | 2021.12.13 |
---|---|
배관 진동에 대한 정성적 평가 기준 (0) | 2021.10.26 |
EI Guidelines for AIV (0) | 2020.09.17 |
Cyclic Allowable Stress Criteria (0) | 2020.09.02 |
ISO 1940-1 (2003) (0) | 2020.08.27 |